<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>International Center for EMECS &#187; Effect of cooling load on air conditioning system of computer case by thermoelectric peltier sheet｜International Center for Environmental Management of Enclosed Coastal Seas</title>
	<atom:link href="https://www.emecs.or.jp/en/tag/adirek-suriyawong/feed" rel="self" type="application/rss+xml" />
	<link>https://www.emecs.or.jp/en</link>
	<description>he International EMECS Center is an organization established for promoting international exchanges on not only coastal but also catchment areas of the enclosed coastal seas in a wide range of fields such as research, policy, civic action, education and industrial activities and so forth to solve the problem on the environmental conservation of enclosed coastal seas in the world such as the Seto Inland Sea (Japan), the Chesapeake Bay (USA), the Baltic Sea (Northern Europe), and the Mediterranean Sea (Southern Europe).</description>
	<lastBuildDate>Tue, 13 Oct 2026 01:11:46 +0000</lastBuildDate>
	<language>ja</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=4.0.1</generator>
	<item>
		<title>Effect of cooling load on air conditioning system of computer case by thermoelectric peltier sheet</title>
		<link>https://www.emecs.or.jp/en/emecs12-conference/emecs12-11/132</link>
		<comments>https://www.emecs.or.jp/en/emecs12-conference/emecs12-11/132#comments</comments>
		<pubDate>Mon, 05 Nov 2018 15:16:00 +0000</pubDate>
		<dc:creator><![CDATA[owner@emecs_or_jp]]></dc:creator>
				<category><![CDATA[Poster Presentation]]></category>
		<category><![CDATA[Adirek Suriyawong]]></category>

		<guid isPermaLink="false">https://www.emecs.or.jp/en/?p=1872</guid>
		<description><![CDATA[Effect of cooling load on air conditioning system of computer case by thermoelectric peltier sheet Adirek Suri [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>Effect of cooling load on air conditioning system of computer case by thermoelectric peltier sheet<br />
Adirek Suriyawong*<br />
Department of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Prince of Chumphon Campus, Chumphon 86160, Thailand<br />
The experimental study was the air conditioning system of computer case by thermoelectric peltier sheet. The peltier sheet are used the temperature difference of cold side and hot side. The cold side of thermoelectric sheet was installed the heat sinks with heat removing from a thermoelectric sheet into a surrounding and, the cold side of thermoelectric sheet was installed the heat sinks with the heat absorption of computer case. The apparatus of cooling loads generation was installed in the computer case. The computer case volume is 450x395x240 cubic millimeter. The cooling loads tested with various concentrations of 0, 60, 120, 180 and 240 W. The results also indicate that the COP increased with the cooling loads increasing. Moreover, the experimental results show that the temperature inside computer case increased with the cooling loads increasing, because the temperature of computer case increased with decreasing the temperature different of cold side and hot side.<br />
Keywords: Air conditioning system, Thermoelectric, Peltier, Computer case, Electronic box<br />
*Presenter: E-mail: adirek.su@kmitl.ac.th</p>